Sender |
Complaint/Query |
Reply/Action to be taken |
a.
|
Ooi Say Kow
|
Architect Chong Kum Kwan
& Associates had sent reply to PAM instructing not
to issue any plans or answer any queries requested by
Ooi Say Kow because they had hand over the case to their
solicitor - M/s Thayalan & Associates (Advocates
& Solicitors). Ooi Say Kow may refer directly to
their company for any queries so they can seek advice
from their solicitor.
|
None to be taken
|
b
|
Ou Yang Chow Min
|
He was invited by a Receiver
and Manager Consultant to participate in an abandoned
project which has a design architect and separate submitting
architect. He queried, whether he can take the task
of new architect for the project without the discharge
of the existing submitting architect?
|
No. Please refer to the LAM
Guidelines on the Letter of Release. |
c.
|
Mack
|
He is concerned about fire rating and
sound proofing features of the current construction
of party walls for 2 storey link house.
Questions:
1. What building codes/laws governs the use of cement
sand bricks as party walls and the method of construction?
2. Who is monitoring the method of construction and
to ensure that every cement sand brick laid is fire
rated?
3. The S&P unfortunately does not state the type
of bricks use or the thickness of walls that the developer
need to deliver - hence, are buyers getting short change?
|
1. UBBL
2. The Architect and Fire and Rescue Department (BOMBA).
3. The second Schedule requires the Approval Building
Plan to be attached. Buyers should not sign the S&P
if they are not happy with the Agreement.
.
|
d.
|
Tan TT
|
Need opinion/advise on:
1. When the architect had taken more than 30 days to
issue certificate for his work done without assigned
any reason, what he can do?
2. When the consultant QS had requested Architect to
issue instruction for QS to carry out the evaluation
of his direct cost and expense for more than 21 days
and the architect has not reply nor issue such instruction
without assign any reason, what he can do?
3. If he will commence or file a complaint against this
architect, what are the procedures involve?
|
1. Assume that period of interim certificates
in clause 30 is 30 days, the Architect is on breach
of his duty under the contract.
2. Apply for arbitration under clause 34 for withholding
certificate.
3. Write to LAM who is the Statutory body governing
the practice of Architects.
|
e.
|
Lim Chee Meng
Lee Yuet Wah
Lim Pui Ying
|
Appointed H.J. Chua & Associates as
an Architect to erect a 3 storey bungalow house on Lot
P.T. 1072, Jln Balau, Bukit Damansara, Kuala Lumpur.
They complaint that the Architect and the Contractor
had failed to execute their duties sufficiently and
diligently which caused the non-completion of the premise
on time. They wanted PAM to investigate whether the
Architect has breached the Architect Rules 1996 or any
other statutory provisions as alleged?
|
PAM to write standard letter to H.J. Chua & Associates
for comments and copy letter to the complainants.
|
| f. |
Hilmi Faridah Architects Sdn. Bhd. |
Reply letter to PAM with explanations.
|
PAM had sent reply from Architect to Mirage
Home Sdn Bhd. |
g.
|
Song Kong Lam &
Lim Swee Beet
|
In Aug 2001 they bought a bungalow at
Jln Permatang Damar Laut, Penang. The house was certified
on Aug 2003. But after they made payment to the developer
and collected the key of the house, they found that
the electrical wiring surrounding the house was not
concealed. They also noted that tarring of the roads
servicing the housing area was only carried out 4 months
after the issuance of the Architect's said certificate.
They believe that the Architect had issued the certificate
not because the housing unit was completed and ready
for handing over but to enable the developer to collect
the progress payment as well as for developer to get
away with not having to pay them late delivery charges.
They ask PAM to assist whether the Architect is justified
in issuing the said certificate in Aug 2003. |
Based on the facts provided, the Architect
was not justified to issue the certificate and to assist
you in this matter, we enclose herewith the LAM Guidelines
for Certification for your reference |
| Name of Committee |
Official and alternate representatives
to attend / be nominated |
| PAM Rep |
Alternate Rep |
Current Rep |
CIDB - JK Pembangunan Modul Latihan Untuk
'Safety Officer' yang Berdaftar Dengan JKKP
Date: 27 July 2004
Time: 9.30 am
Venue: Bilik Mesyuarat Bhg. Pemb. Teknologi CIDB, Tingkat
8, Grand Seasons Avenue, No.72, Jalan Pahang, Kuala
Lumpur.
|
Ar Chris Yap Seng Chye
|
Ar Jerry Sum
|
|
| SIRIM - Technical Committee on Dry Fire
Protection System |
Note:
To nominate new representative
|
|
|
| SIRIM - JK Standard Perindustrian bagi
Besi dan Keluli (ISC P)
|
Note:
To nominate new representative |
|
|
| SIRIM - JK Teknik "Code of Practice
for Design of Structural Steel" Untuk Penyediaan
Standard Malaysia |
Note:
To nominate new representative |
|
|